MODELING NOTES FOR ASHRAE STANDARD 140 A. SOFTWARE INFORMATION 1. SOFTWARE VENDOR: REM/Rate LLC. 2. SOFTWARE NAME: REM/Rate 3. SOFTWARE VERSION: 2025 4. OPERATING SYSTEM REQUIREMENTS: Windows 10 Windows 11 5. APPROX HARD DISK SPACE REQUIRED FOR INSTALLATION: 3GB 6. MINIMUM RAM REQUIRED FOR SOFTWARE OPERATION: 8GB 7. MINIMUM DISPLAY MONITOR REQUIREMENTS: 1024x768 8. OTHER HARDWARE OR SOFTWARE-RELATED REQUIREMENTS: REM/Rate serves as an input generation, data management, HPXML translation, and results reporting application. Energy simulation calculations for the ANSI/ASHRAE Standard 140 tests are performed using OpenStudio-ERI, which utilizes OpenStudio-HPXML and EnergyPlus. ANSI/ASHRAE Standard 140 test cases employed for RESNET software accreditation consist of building fragments that do not represent complete residential buildings and therefore do not satisfy the input validation requirements normally enforced for production residential energy ratings. For execution of the ANSI/ASHRAE Standard 140 accreditation tests, REM/Rate provides a dedicated accreditation mode that: - Reads the accreditation test-case building files directly from a specified directory. - Generates HPXML representations of the building files without applying normal residential model validation checks. - Invokes OpenStudio-ERI in ANSI/ASHRAE Standard 140 mode. - Passes the required options to bypass standard residential input validation and apply the assumptions prescribed for the ANSI/ASHRAE Standard 140 test suite. - Collects simulation results and exports them to a spreadsheet format for comparison against ANSI/ASHRAE Standard 140 reference results. The ANSI/ASHRAE Standard 140 test results submitted herein were produced using the same automated accreditation workflow that is used by REM/Rate to maintain RESNET accreditation. The simulation calculations themselves are performed by OpenStudio-ERI/OpenStudio-HPXML and EnergyPlus. REM/Rate does not modify the underlying simulation algorithms, ANSI/ASHRAE Standard 140 test implementations, or EnergyPlus calculation engine for the purpose of ANSI/ASHRAE Standard 140 testing. The ANSI/ASHRAE Standard 140 test results submitted by REM/Rate were validated using the RESNET ANSI/ASHRAE Standard 140 accreditation spreadsheet. All required test cases produced results within the acceptance ranges specified by the accreditation procedure. B. REPORT BLOCK FOR ALTERNATIVE MODELING METHODS NONE C. REPORT BLOCK FOR EQUIVALENT MODELING METHODS NONE D. REPORT BLOCK FOR USE OF NON-SPECIFIED INPUTS NONE E. REPORT BLOCK FOR OMITTED TEST CASES AND RESULTS The ANSI/ASHRAE Standard 140 results submitted herein were generated using the same automated accreditation workflow employed for REM/Rate RESNET software accreditation. The test suite executed for this submission consists of the ANSI/ASHRAE Standard 140 test cases required by the RESNET software accreditation procedure. Test cases not required by the RESNET accreditation procedure were not executed and are therefore not reported. Consequently, the Tier 2 test cases identified in the Standard 140 RESULTS7-2 reporting workbook (L165AC, L165AL, P100AC, P105AC, P110AC, P140AC, and P150AC) were not executed as part of the REM/Rate accreditation workflow and are omitted from the submitted results. No simulation results have been excluded for any test case that was executed as part of the accreditation test suite. F. REPORT BLOCK FOR CHANGES TO SOURCE CODE FOR THE PURPOSE OF RUNNING THE TESTS, WHERE SUCH CHANGES ARE NOT AVAILABLE IN PUBLICLY RELEASED VERSIONS OF THE SOFTWARE REM/Rate includes an accreditation testing mode intended solely for execution of the ANSI/ASHRAE Standard 140 test suite used for RESNET software accreditation. This functionality is not exposed during normal residential energy rating operation. This mode bypasses the normal residential building validation checks performed by REM/Rate and allows generation of HPXML files corresponding to ANSI/ASHRAE Standard 140 building fragments. It also invokes OpenStudio-ERI using options that bypass standard input validation and apply ANSI/ASHRAE Standard 140 assumptions. These changes affect only the preparation and execution of test cases. No modifications were made to the underlying simulation algorithms, ANSI/ASHRAE Standard 140 test implementations, or EnergyPlus calculation engine used to generate the reported results. The ANSI/ASHRAE Standard 140 test cases required for RESNET accreditation contain assumptions that are not represented directly in the REM/Rate building file. Accordingly, limited modifications are made to the generated HPXML prior to simulation to ensure that the model presented to OpenStudio-ERI conforms to the requirements of the ANSI/ASHRAE Standard 140 test procedures. These adjustments are consistent with the assumptions required by the RESNET ANSI/ASHRAE Standard 140 accreditation procedure and are applied solely for execution of the accreditation test suite. Specifically, the generated HPXML is adjusted as follows: - Add the ApplyASHRAE140Assumptions extension flag used by OpenStudio-ERI. - Add plug loads and associated schedules, as required. - Add miscellaneous loads and associated schedules, as required. - Set roof area explicitly rather than deriving roof area from roof pitch. - Remove CO2 index reporting inputs. - Add wood siding to above-grade walls as per the test requirements. - Set attic ventilation rate explicitly as per the test requirements. - Set building occupancy to zero as per the test requirements. - Remove residential appliance definitions not applicable to the ANSI/ASHRAE Standard 140 test case being executed. G. REPORT BLOCK FOR ANOMALOUS RESULTS NONE